Anechoic Chamber for 10m testing on Telecommunication & ITE applications

This 10m Semi-Anechoic Chamber has been provided to a major Korean supplier of Telecommunication equipment for full-compliance radiated emission measurements in 10m test distance and for radiated immunity testing in the 3m test distance. The facility covers the whole frequency range 26MHz to 40GHz in accordance with the latest editions of International, US and European standards for EMC testing and site validation. Listing of the 10m site as FCC facility, getting European accreditation or VCCI recognition are both possible.

Typical EUTs (Equipments Under Test) are telecom equipment as well as information technologies equipment (ITE).

The chamber’s modularity for RF shielding and RF absorber lining is a proven advantage should the chamber ever be relocated or expanded.

 

Technical Data

Dimensions: 19.6m x 12.4m x 7.5m (L x W x H)

 

Radiated Emission Measurements

  • 30MHz to 1GHz: Full compliance with ANSI C63.4 and CISPR 16-1-4 in 10m measuring distance, ±3.5dB
  • 1GHz to 18GHz: recently calibrated to the newest CISPR 16-1-4, i.e. sVSWR in 3m measuring distance, <6.0dB
  • Quiet Zone: 3m cylinder, height 2m, floor standing

 

Radiated Immunity Tests

  • 80MHz to 18GHz: Full compliance with EN 61000-4-3
  • 1.5m x 1.5m uniform field in 3m test distance

 

Features

The chamber is fitted with a 2.5m large sliding gate inclusive of automatic ramp for easy access of the EUT and two 0.9m large personnel doors; a 3m diameter turntable, an antenna mast and controller and additional RF shielded rooms, for the power amplifiers and a test equipment control room, were  installed.

Other customized solutions to suit the customer’s test and measurement needs were provided. These included a RF shielded CCTV camera systems, audio intercom, smoke detection, fiber optic converters, RFI power line and signal line filters, RF absorber lining with 18” and 30” matched hybrid RF absorbers with light reflective white caps.

contact
print
to the top
Copyright Albatross Projects 2011 Impressum  |  Sitemap